A falling display or projector can kill someone. Mounting is the part of the job with no room for shortcuts.

Respect the ratings

Every mount and every anchor has a load rating. Use a mount rated for the actual load, including the device and any accessories, and follow the manufacturer's instructions for fasteners. Never exceed a rating, even by a little. If the device is too heavy for the mount on the truck, get the right mount.

Anchor to structure

  • Wood studs: lag into the center of the studs or into blocking added for the purpose. Drywall anchors alone are not suitable for large displays.
  • Metal studs: use the mount maker's approved method, usually with added backing.
  • Concrete and block: choose anchors rated for the load and the material, and install them exactly as the anchor maker specifies (hole size, depth, cleaning, torque).

Before drilling, check for hidden electrical, plumbing, gas and structural elements.

Ceilings

A suspended ceiling grid is not designed to carry projectors or heavy speakers. Support them from the building structure or rated supports, and add a safety cable to projectors and other overhead devices where required. In seismic regions, the engineer or local code may require extra bracing; follow the drawings.

Get the position right

Mounting height and position affect viewing angles, camera framing and accessibility. Confirm against the drawings, mark and level before final fastening. Moving a mount after the fact means patching the wall and losing a day.