Audio system design
Loudspeaker coverage, room acoustics and reverberation, noise, microphones, feedback and echo cancellation.
About 14 minutes
Loudspeaker coverage
Speech reinforcement and program audio should be even across the listening area at ear height (seated or standing, depending on the room). With ceiling speakers, each speaker covers a circle at ear height that depends on its dispersion and the distance from the speaker to the ears. Lower ceilings mean smaller circles, so speakers must be closer together.
Room acoustics
- Reverberation time (RT60) is how long sound takes to decay by 60 dB after the source stops. Long reverberation smears speech and makes echo cancellation work harder.
- Background noise, often from HVAC, is usually specified with NC (noise criteria) ratings. Quiet rooms need the mechanical design to cooperate.
- STI (Speech Transmission Index) measures intelligibility from 0 (poor) to 1 (excellent).
Acoustic treatment often improves a conference room more than any equipment upgrade. Raise it early with the architect.
Microphones and feedback
The more microphones open at once, the less gain you get before feedback: about 3 dB less for every doubling of open microphones. Use automatic mixing to keep only the needed microphones open, keep microphones away from loudspeaker coverage, and pick pickup patterns that suit the seating.
Echo cancellation
In conferencing, far-end audio comes out of the room's speakers and back into the microphones. Acoustic echo cancellation (AEC) removes it, using a reference of the far-end signal. Route the reference correctly, and give AEC a fair chance with sensible room acoustics and microphone placement.
Create a free account to track which lessons you've finished and take the exam.